GB
Use of the kitchen hoodInstallation
? The kitchen hood is equipped with a multistageDo not tile, grout or silicone this appliance to the
fan.wall. Surface mounting only.
Do not fix chimney flue to furniture or fly over
Control panel - Fig. 1shelves unless the chimney flue can be easily
a. Indicator lightremoved, in case maintenance is ever required.
b.Lighting on/off buttonThis cooker hood is designed to be installed onto
a corner of a kitchen.
c. Hood on/off button
When installed, the distance between hood and
d. e. f.Button used to adjustburners must be not less than 65 cm. above
working speed 1 (d.), 2 (e.), 3 (f.)
electric burners or 75 cm. above gas or mixed-
? For best performance, you are advised to usefuel burners.
speed one or two in normal conditions, and
speed three in the presence of high levels ofElectric connection
vapour.
? Lighting improves visibility in the cooking area,Before completing any connection, make sure the
house voltage corresponds with the voltage
and should therefore be used.indicated on the label affixed inside the hood
? It is recommended that you turn the hood on a
few minutes before you start cooking, andIt is advisable to call a qualified technician to make
the electrical connection.
keep it switched on for at least 5 minutes after
you finish.Appliance fitted with plug.
Connect it to a socket which conforms with
Use:Two systems are availablecurrent regulations.
If you intend to connect it directly to the electric
mains, remove the plug and fit an approved
Exhaust mode (A)bipolar switch with a minimum contact opening of
Vapours are extracted outside through anno less than 3mm.
exhausting pipe that is affixed to the connectionIf the plug is not accessible once it has been
ring above the hood.inserted in the socket, it will however be
Diameter of the exhausting pipe must be equal tonecessary to fit an approved bipolar switch with
that of the connection ring.a minimum contact opening of no less than 3mm.
In the horizontal runs the duct must be slightly
Appliance without plug
slanted (about 10°) and directed upwards to ventFit an approved plug or an approved bipolar
the air easily from the room to the outside.
Attention!switch with a minimum contact opening of not
less than 3mm.
If the hood is supplied with carbon filter,
then it must be removed.The manufacturers are not liable for any problems
caused by the user?s failure to observer the
Filter version (F)above instructions.
The air is filtered through a carbon filter (for its
installation see paragraph "Carbon filter") andWarning!
recirculated into the room through the grating on? The hood cannot be connected to flues of
the lower side of the chimney.other appliances that run on energy sources
Attention!other than electricity.
If the hood is not supplied with carbon filter,? When the hood is used at the same time of
then it must be ordered and mounted.other appliances that run on energy sources
This version is used when there is no exhaustother than electricity, provision must be made
duct for venting outdoors or when it is impossiblefor an adequate supply of air.
to install one.
? No food must be cooked flambé underneath
the hood.
The use of an unprotected flame is dangerous
for the filters and could cause fires.
8 |